Three-phase isolating transformers

download PDF file
Type:
associated transformer not resistant to short circuit
Primary voltage: up to 1000V
Secondary voltage: a selection of voltages between 50 and 1000V
Connection between the phases: optional
Vectorial group: optional
Transformers to be incorporated into specific electrical equipment
Reference standards: CEI 96-3; EN 61558-1; CEI 96-8; EN 61558-2-4

PRODUCT NOT INTERESTED BY 204/108/CE NORM RELATED TO ELECTROMAGNETIC COMPATIBILITY EMISSIONS.

PART
NUMBER

POWER
[kVA]

Height [mm]

Width [mm]

Depth [mm]

Weight [kg]

Mounting  A [mm]

Mounting
B [mm]

BTTT182

0.5

160

180

140

6.5

150

77

BTTT183

1

160

180

160

11

150

97

BTTT184

1.5

210

240

145

16

200

88

BTTT185

2

210

240

150

18

200

98

BTTT186

2.5

210

240

160

19.5

200

108

BTTT187

3

210

240

170

21

200

123

BTTT188

3.5

255

300

180

29

250

105

BTTT189

4

255

300

190

30.5

250

115

BTTT190

5

255

300

200

36

250

125

BTTT191

6

255

300

220

40.5

250

135

BTTT192

7

255

300

230

46

250

145

BTTT193

8

310

360

280

48

325

145

BTTT194

10

310

360

300

55

325

155

BTTT195

12

360

420

370

97

375

155

BTTT196

15

360

420

380

140

375

165

BTTT197

20

360

420

400

155

375

175

BTTT198

25

410

480

420

170

425

210

BTTT199

30

410

480

430

190

425

220

BTTT200

40

410

480

450

210

425

240

BTTT201

50

450

480

400

240

225

210

BTTT202

60

550

540

400

270

225

210

BTTT203

70

560

540

460

330

225

210

BTTT204

80

560

540

460

350

480

210

BTTT205

100

580

600

480

400

560

220

Notes:
1.Drawings, measurements and weights are indicative and can change without notice.
2.For powers and voltages not reported in the table or for special construction requirements, request the characteristics of the transformers from our technical office.
3.Transformers with secondary voltages below 50V can be manufactured.

METALLIC BOX CASED ESECUTION

Type: associated transformer not resistant to short circuit
Primary voltage: up to 1000V
Secondary volyage: a selection of voltages between 50 and 1000V
Connection between the phases: optional
Vectorial group: optional
Transformers to be incorporated into specific electrical equipment
Execution:
- In metallic container with protection degree of IP55, RAL7032 paint, for powers below 30kVA (figure no.1)
- In metallic container with protection degree of IP23, RAL7032 paint, for powers from 30kVA and over (figure no.2)
Reference standards: CEI 96-3; EN 61558-1; CEI 96-8; EN 61558-2-4

PRODUCT NOT INTERESTED BY 204/108/CE NORM RELATED TO ELECTROMAGNETIC COMPATIBILITY EMISSIONS.

PART
NUMBER

POWER
[kVA]

Height
B[mm]

Width
A[mm]

Depth
C[mm]

Weight
[kg]

Figure n°

BTTTC183.1

1

350

250

250

16.5

1

BTTTC185.1

2

350

250

250

23

1

BTTTC187.1

3

350

250

250

26

1

BTTTC189.1

4

500

400

250

40.5

1

BTTTC190.1

5

500

400

250

46

1

BTTTC191.1

6

700

500

250

54.5

1

BTTTC192.1

7

700

500

250

59

1

BTTTC193.1

8

800

600

300

63.5

1

BTTTC194.1

10

800

600

300

70

1

BTTTC195.1

12

900

600

300

100.5

1

BTTTC196.1

15

1000

800

300

155

1

BTTTC197.1

20

1000

800

300

171.5

1

BTTTC198.1

25

1200

800

300

187

1

BTTTC199.1

30

600

700

460

210

2

BTTTC200.1

40

800

900

650

230

2

BTTTC201.1

50

800

900

650

252

2

BTTTC202.1

60

800

900

650

282

2

BTTTC203.1

70

800

900

650

355

2

BTTTC204.1

80

800

900

650

376

2

BTTTC205.1

100

1000

1000

1000

425

2

Notes:
1.Drawings, measurements and weights are indicative and can change without notice.
2.For powers and voltages not reported in the table or for special construction requirements, request the characteristics of the transformers from our technical office.
3.Transformers with secondary voltages below 50V can be produced.